Monday 31 July 2017

Giving users access to the Service Request Work Center and Data Set Designer in Maximo Asset Management 7.6.0.6


Problem(Abstract)

The object structure requirements for the Service Request Work Center and the Data Set Designer were documented incorrectly for Maximo Asset Management 7.6.0.6.

Resolving the problem

The following website provides details on how to give users access to Work Centers and the Data Set Designer:
In addition to the object structures listed for the Service Request Work Center, the following object structures are required: MXNOTIFICATION, MXAPILOCATION, MXAPILOCANCESTOR, MXAPIASSET, and MXAPIPERUSER.
The complete list of object structures for the Service Request work center is:
MXAPISR (Read, Save, Delete, Insert)
MXAPIWORKLOG (Read, Save)
MXAPIBOOKMARK (Read, Delete)
MXAPITKCLASS (Read)
MXAPITKTEMPLATE (Read)
MXAPIPERUSER (Read)
MXNOTIFICATION (Read, Save)
MXAPILOCATION (Read)
MXAPILOCANCESTOR (Read)
MXAPIASSET (Read)
In addition to the object structures listed for the Data Set Designer, the MXAPIENDPOINT object structure is required with read access. Additionally, the MXAPIANALYTICDATASET object structure requires read, save, change status, and delete access.